a) Determine safety signs: Based on the market requirements of the product to be sold, select the safety certification mark and safety standards (UL standard or IEC standard fuse tubes) for the fuse tube.
b) Determine the external dimensions: Based on the installation space, determined safety certification marks, and safety standards, select the external dimensions of the fuse tube.
c) Determine the model: Based on the current characteristics of the protected circuit, select the model of the fuse tube. For example, if the current characteristic of the protected circuit is constant current, a fast fuse type is selected.
d) Determine rated voltage: Determine the rated voltage of the fuse tube based on the input voltage and usage requirements of the protected circuit. For example, if the input voltage of the protected circuit is 220V, a fuse tube with a rated voltage of 220V or higher must be selected, including 250V, 300V, 350V, etc; But considering cost factors, there is no need to choose excessively high rated voltage.
e) Determine the minimum rated current: Based on the stable working current of the protected circuit and the relevant usage loss coefficient, preliminarily determine the rated current of the fuse tube. For example, if the stable working current of the protected circuit is 1A and UL standard delay fuse tubes are selected, and the working environment temperature is about 80 ℃, the minimum rated current of the fuse tube is selected as 1A x 1.25 ÷ 0.5=2.5A.
f) Determine the minimum I2T of the fuse tube: Based on the surge I2T of the protected circuit, determine the I2T of the fuse tube. For example, the surge I2T of the protected circuit is 1 (A2S). To ensure that the fuse tube can withstand more than 100000 impacts, the I2T of the fuse tube should be greater than 1 ÷ 0.2=5 (A2S).
g) Determine the rated current of the fuse tube: Based on the minimum rated current and minimum I2T value, check the corresponding model specifications in the product catalog, and select the primary rated current specification that is both greater than the minimum rated current value and its I2T value is also greater than the minimum I2T value as the rated current of the selected fuse tube. For example, based on the minimum values above, (1) if the rated current of 2.5A for I2T is 4.3 A2S, and 3A for I2T is 5.4 A2S, then 3A is taken as the rated current for selecting the fuse tube; (2) If the I2T with a rated current of 2A is 5.3 A2S and the I2T with a rated current of 2.5A is 7.6 A2S, then 2.5A is taken as the rated current of the selected fuse tube.